Eyeworld Nov, 2016
Long eye: benchmark: > 26mm or 28mm
PRE-OP
Check the retina condition
INTRA-OP
1. pupillary block: a second instrument can lift the iris off the capsule to allow fluid to circulate back to the PC.
2. DO NOT enter the wound irrigating
IOL CALCULATION
1. >25.2mm: Wang-Koch AL adjustment, with Holladay1, Haigis , SRKT and HofferQ
PATIENT CONVERSATION
1. plano or a little bit of myopia
2. Decent chance of LASIK enhancement if expecting spectacle independence